Lighting, measurement and comparison tools to verify design compliance.

Visual InspectionVT

Overview

Visual inspection is the first and most widely used NDT method. Using proper lighting, gauges and comparative tools, our inspectors verify that welds and components conform to drawings and code requirements.

We record weld profile, surface condition and dimensions, and flag anything that needs follow-up with radiography, ultrasonic or surface methods.

What it finds

  • Undercut, overlap and excess reinforcement
  • Surface porosity and visible cracks
  • Misalignment and distortion
  • Incorrect weld size and profile

Where we use it

  • Fit-up and in-process weld checks
  • Final weld acceptance
  • Castings and forgings on receipt
  • Shutdown and in-service inspection

At a glance

ToolsWeld gauges, magnifiers, borescopes, calibrated lighting
Typical codesASME Sec V Art. 9, AWS D1.1, ISO 17637
DeliverablesVisual inspection report with photographs

Codes listed are typical. We work to the specification and acceptance criteria in your purchase order.